51,0500
56,1000
02422471224
     05076167225  
Yeni
Populer
Outlet
Kampanya
Hediyeli
Özel Fiyat
PWR On
The switch is powered on.
PWR Off
The switch is powered off.
Port Indicator On
The corresponding port is connected to a network device but no activity
Port Indicator Flashing
Data is transmitting through the corresponding port.
Port Indicator Off
No device is connected to the corresponding port.
port composition
port 1-8: 10/100/1000Mbps PoE port
Port 9-10: 10/100/1000Mbps RJ45 uplink port
Port 11-12: 10/100/1000Mbps SFP uplink port
Backplane bandwidth
24Gbps
MAC address table
4K
Subcontracting rate
35.714Mpps
Toggle delay
<5us
PoE port
port 1-4 support 802.3bt, Max. Port Power 90W.
port 5-8 support 802.3at/af, Max. Port Power 30W.
Network medium and transmission distance
1000Base-T: 4 pairs of Cat5e or higher UTP/STP (≤100m)
100Base-TX: 2-to-Cat5 (Cat5) or above UTP/STP (≤100m)
10Base-TX: 2 to Cat 5 (Cat6) or above UTP/STP (≤250m)
Ethernet protocols and standards
Data transfer rate
Power Specifications
Power terminals
Overload protection
Reverse polarity protection
Redundant protection
temperature
humidity
elevation
Operating: Up to 6500 ft (2000 m)
Storage: Up to 6500 ft (2000 m)
IEC61000-4-2 (ESD): ±8kV (contact), ±15kV (air)
IEC61000-4-3 (RS): 10V/m (80MHz-2GHz)
IEC61000-4-4 (EFT): Power Port: ±4kV; Data Port: ±2kV
IEC61000-4-5 (Surge): Power Port: ±2kV/DM, ±4kV/CM; Data Port: ±2kV
IEC61000-4-6 (CS): 3V (10kHz-150kHz); 10V (150kHz-80MHz)
IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s)
IEC60068-2-6 (Vibration)
IEC60068-2-27 (Shock)
IEC60068-2-32 (Free Fall)
Bare metal
44.5mm x 150mm x 118mm(W×H×D)
Fill guard
The switch is equipped with a pearl cotton sleeve for three-dimensional protection
Packing quantity
10PCS(CARTON)
Approvals
CE, FCC, RoHS
Environmental Limits
Operating Temperature: -30 to 70°C
Storage Temperature: -45 to 85°C
Ambient Relative Humidity: 5 to 95% (non-condensing)
MTBF
360,000 hours
Stacking limit
In the state of complete packaging, the maximum limit is 4 layers
Precautions
The storage warehouse should be clean, ventilated, free of corrosive gases, flammable, explosive and other corrosive chemicals.
Keep away from heat sources and strong mechanical vibrations.
Storage period
According to the above requirements, reasonable storage can last for one year, and it is recommended to re-inspect and use after 2 years
other
There should be a label on the packaging box to indicate the product model, code and quantity
Mount
DIN-Rail